Skip to content
ENQUIRY BASKET · 0
Empty. Add products with the + on any card, then send the whole list as one enquiry.
RAPID DIAGNOSTICS · 1ST CHECK · 42 FORMATS

Rapid diagnostics · Meet 1st Check

One drop.
An answer in minutes.

42 rapid formats across malaria, dengue, HIV, hepatitis, syphilis, typhoid and pregnancy. Cassettes and strips that need no instrument, no cold chain and no interpretation beyond two lines, made and batch-released in the same ISO 13485:2016 building as the rest of the catalogue.

1st Check, the Reckon mascot, tipping a drop into a rapid test cassette
S C T
42Rapid test formats
C + TResult window: control and test lines
3Sample types: serum, plasma, whole blood
0Instruments or cold chain needed

Two lines of rapid tests.

Cassettes and strips read by eye, and immunofluorescence cartridges read on a small point-of-care reader. Both ship from the same line.

How one is made.

Every cassette on this page goes through the same seven stages. This is a malaria antigen card, RDT-MAL.102. The strips are the same minus the plastic housing. Immunofluorescence cartridges are a different product and are not made this way.

Drawing, not photography. The stages are the real sequence; the picture is a diagram.

1 T C Malaria Ag S P.f/Pan SiO RECKON MALARIA ANTIGEN CARD LOT 26CY102 RECKON MALARIA Ag P.f/Pan 50 TEST RDT-MAL.102

01 of 07

Nitrocellulose membrane

A roll of nitrocellulose arrives with a stated pore size. Everything the test does happens on this strip: the sample walks along it by capillary action, and nothing pushes it.

  1. Nitrocellulose membraneA roll arrives with a stated pore size. The sample walks along it by capillary action.
  2. Antibody stripingA dispensing head lays two lines wet: the test line for the malaria antigen, the control line that proves the test ran.
  3. LaminationSample pad, conjugate pad and absorbent pad are laminated either side onto a backing card.
  4. CuttingThe laminated sheet is cut across into strips, each one a complete test.
  5. AssemblyA strip is clipped between the two halves of the housing, the well over the pad and the window over the lines.
  6. PouchingA desiccant goes in, the jaws close, and the foil is sealed and lot-coded.
  7. CartonFifty pouches to a printed carton, released against the batch record before it leaves.

How a test reads.

  • Result windowTwo lines. The control line (C) shows the test ran; the test line (T) is the result. Each datasheet states how to read that product.
  • Sample typesSerum, plasma or whole blood, depending on the test. Each datasheet states which, and the volume of the drop.
  • POCT kitsPoint-of-care packs ship with a lancet and a swab, so a fingertip sample can be taken where the test is run.
  • StorageNo cold chain in transit or on the shelf. Storage conditions and shelf life are printed on the box and in the datasheet.

Disease areas.

Need a rapid test for your market?

Tell us the disease area, the format and the volumes. We reply from Vadodara with a quotation, the datasheet, and what your registration will need.

Tell us what
your lab needs.

ENQUIRE NOW →